PVC  volumetric flow meter Impeller reel fan with  2 magnetic contacts. Typically fails if there has been a build-up of minerals such as magnesium or lime on the metal contacts. Usually, the flow meter top and O ring are replaced at the same time - see below.


You will need to replace the flow meter if: 

  • If the volumetric panel no longer programs - (Could also be PCB failure or panel needs to be replaced )
  • If the volumetric button no longer works - Could also be panel needs to be replaced.
  • If the LED no longer lights up on the flow meter (if you have an led, some flowmeters don't have LED light ) - This means that the impeller is not making contact with metal due to mineral buildup

 

Specifications:
  • Material: S. Steel + PVC
  • Size: 14.3mm height  x 27mm wide
  • Gicar code:6.9.23.05G 
  • Made in Italy

 

Search terms:

Gicar volume metric flow meter plastic reel, Gicar 6.9.23.05G

Fits most models including:
  • AZKOYEN: AZ04, BRAVO, VIENNA
  • ASTORIA CMA : ADRIA, ARGENTA, BRAVA, CALYPSO, CK, CKE, CKX, CKXE, DENISE, DIVINA, DORA, GLORIA, GLORIA R12, LISA, PERLA 4D, PLUS 4 YOU, PRATIC, PRATIC NEW, SIBILLA, TANYA, VANIA
  • BEZZERA: B2000, B2006, B2009-COMPACT, B2013, B3000, B4000, B6000, BZ35, BZ40, C2013 COMPACT, EBBIS, ELLISSE, GALATEA, PROEX, VERTICALE
  • BFC: CLASSICA, DELUX, GALILEO, GRANDOGE, IMOLA, JUNIOR, LA VITTORIA, LIRA, MARANELLO, MONZA, OPERA
  • CARIMALI: CENTO50, E9, ETA BETA, KIKKO
  • CIMBALI: M15, M20, M22, M27, M-27, M28, M29, M30, M31, M32
  • ELEKTRA: CLASSIC, KAPPA, MODERN, SIXTIES
  • EXPOBAR: CARAT, DIAMANT, ELEN, EXPRESSO, G10, MARKUS, MARKUS SILVER, MEGACREM, MINI COMPACT, MONROC, NEW ELEGANCE, OFFICE
  • FAEMA: COMPACT, DUE, E91, E92, E97, E98, EXPRESS, SMART
  • FIORENZATO C.S.: BRICOLETTA, CAMPANILE, COLOMBINA, DUCALE, FENICE, LIDO, MURANO, PIAZZA SAN MARCO, RIO, VENEZIA, VOLANTE
  • FUTURA: F100
  • FUTURMAT-ARIETE  :ARIETE, F3, RIMINI
  • GAGGIA SPAGNA :BELLA, KB, NERA
  • GRIMAC:  ECLISSE, G10, G11, MIA, NEW CIALDA VAPOR 2, NEW-CIALDA-VAPOR, SELENITE-DOUBLE, TEN, TWENTY, ZOLA-I, ZOLA-II
  • ITALCREM: CAPRI, IT4
  • LAVAZZA: LB4700
  • MAIRALI :ARIANNE, GIULIETTA
  • MCE: FORMA, NEW START, START, TOUCH
  • NUOVA SIMONELLI: APPIA, AURELIA, AURELIA II, AURELIA II T3
  • ORCHESTRALE: ETNICA, PHONICA
  • RENEKA : CONCEPT, LC, LIFE - LIFE HIGH CUP, OEM, PLUS SERIE PRESTIGE, R80, STREAMLINE, TECHNO, TEMPO, VIVA, VIVA E, VIVA E EVO, VIVA S, XL BASIC, XL PALLAS
  • RHEA VENDORS : Vending machine - EUROPA 2, LUCE, MAXI, MIDI 2, MODA
  • ROYAL: DIADEMA, SYNCHRO
  • SAN MARCO: 100, 105, 85, 95, NEW 105
  • SANREMO: MILANO LX
  • SCALA: BUTTERFLY, CARMEN, EROICA
  • VIBIEMME: CHIMAERA, CUBO, DOMOBAR-SUPER, DOSAPLUS, EVOLUTION, KOMETA, LOLLO, MERCURY, MINIMAX, REPLICA, REVOLUTION, SILVER
  • VICTORIA ARDUINO: ADONIS, VA388 BLACK EAGLE, VENUS-BAR, VENUS-CENTURY
  • VISACREM: BRAVA, NERA
  • WEGA: AIRY, ATLAS, ATLAS 10, COLOSSEUM, COMBINOVA, CONCEPT, ESPRESSA, EURO-2000, FORMULA-MILANO, JUNIOR, MININOVA, NOVA, ORION ECO, PEGASO, POLARIS, SPHERA, START, SYNTESIS, VELA, VENERE, VENUS

 

  1. Make sure that the main water is turned off at the stopcock.
  2. Remove existing flow meter connector wires - - pay attention to where the earth and live were.
  3. Remove the old flowmeter top - 3 screws - a cup full of water will escape from pump pressure.
  4. Replace with new flow wheel and replace inside gasket.
  5. You may have to replace the flowmeter top as well - no need to replace the whole flowmeter as that can be tricky to remove.